First of all, the causes of such failures are:

 

1. Whether the speed throttle valve and the filling interval throttle are closed, the throttle valve cannot be closed

2. whether there is foreign body inside the fast loading the 3-way valve, if yes, please clean up, fast loading the 3-way valve and filling head whether there is air inside the hose, if there is air, as far as possible to reduce or eliminate the air;

3. If the sealing ring is damaged, please replace it if there is any damage.

4. Whether the filling mouth valve core is jammed or delayed open, if there is a card plug, the valve core should be reinstalled. If the delay is opened, the thin cylinder throttle valve shall be adjusted.

5. Quickly install the elastic force of the spiral spring in the control valve of the three-way control valve, adjust the elastic force of the spring, and the spring force will not open.

6. Whether the filling speed is too fast, adjust the filling speed throttle valve, and reduce the filling speed

7. Check and correct all the clamps and pipettes

8. If the magnetic switch is loose, please lock it after each adjustment.

 

Secondly, the water filling machine material has the following reasons:

 

1. Whether the cylinder is in the central position of the cylinder bracket, and if the cylinder is different, please reinstall the position;

2. Whether the cylinder piston and piston rod are fastened, if loose, please lock;

3. Whether the sealing ring of the cylinder piston is damaged, please replace it if there is any damage.

Once again, the water filling cylinder piston is pushed to the top without returning for the following reasons: the position of the flow magnetic switch, press the emergency stop switch, and re-adjust the flow magnetic switch.

pure water 01.jpg 

Finally, there are several reasons why the cylinder of pure water filling machine does not work:

 

1. If the insurance pipe is burnt, if it is burnt out, please replace it

2. If the emergency stop switch is pressed, turn the emergency stop switch to restore it to its original position

3. Whether the piston O ring of the material cylinder is sticky, causes the piston to die and replace the o-type sealing ring

4. If the filling valve core of the filling head is stuck, reinstall the valve core

5. If the gas source and power switch are switched on, turn on the power supply and air source switch

6. Whether the two magnetic switches are in good condition and if there is any damage, please replace them

7. Whether the barometer meets the requirements and whether the air source enters the machine, please access the air source and determine the pressure arrival requirements

8. Whether the cylinder piston is stuck or not, the piston shall be reinstalled.

9. The position of the fixed magnetic switch must be fixed in the rear of the cylinder so that the position of the cylinder can not be moved.